Keor LP – On-line double conversion UPS (tower) – single phase VFI
For security systems, lighting systems, CCTV, servers. Ideal for environments with frequent electrical disturbances
Installation: downstream power generators. Advanced management depending on the battery discharge level
Self-diagnosis. Power factor: 0.9
Automatic internal bypass, manual bypass for external maintenance (optional)
Integrated slot for installing a communication interface for Ethernet network connection, to be ordered separately
Cold Start function
Microprocessor control
Telephone line/Internet protection (RJ 11/RJ 45)
Internal network interface Cat.No 3 108 82 for remote protection of equipment and systems
Remote emergency shutdown function (”Emergency Power Off” – EPO)
Livrare
Informații suplimentare
Rackable

No

Display

LED

Capacitate putere UPS

2700W

RS-232 ports

1

Web-based management

Yes

Management protocols

SNMP

Audible alarm(s)

Yes

Efficiency

90%

Tip UPS:

Online

Form factor

Tower

Capacitate Rack:

None

Ecran LCD:

Nu

Port USB

Nu

Number of input phases

1

AC outlet types

C13 coupler

Serial interface

Yes

Waveform

Sine

Input operation voltage (max)

300 V

Automatic battery test

Yes

Output power

2700 W

Emergency Power Off (EPO)

Yes

Power plug

C20 coupler

AC outlets quantity

8 AC outlet(s)

Serial interface type

RS-232

Output power capacity

3 kVA

Input frequency

45/65 Hz

Battery capacity

7 Ah

UPS topology

Double-conversion (Online)

Crest factor

3:1

Typical backup time at half load

7 min

Input power factor

0.99

Emergency Power Off (EPO) connector

Yes

Output operation voltage (max)

230 V

Input operation voltage (min)

160 V

Output operation voltage (min)

230 V

Output voltage regulation

1%

Power factor

0.98

Output voltage Total Harmonic Distortion (THD)

3%

Audible alarm modes

Alarm when on battery, Fault, Low battery alarm, Overload alarm

Number of type F outputs

2

Protectie supratensiune

Da

UPS-Management

Yes

Management

Da

Operating temperature (T-T)

0 – 40 °C

Battery recharge time

3 h

Battery technology

Sealed Lead Acid (VRLA)

Battery voltage

7.2 V

Depth

151 mm

Operating relative humidity (H-H)

20 – 80%

LED indicators

Yes

Number of batteries supported

6

Noise level

50 dB

Height

444 mm

Weight

2.3 kg

Width

32.2 mm

International Protection (IP) code

IP21

Certification

CE, EN 62040-1, EN 62040-2

Tip:

Online

Alarme sonore

Da

IEC C13

6

Greutate

23 Kg

Putere

3000VA

Interfata

1 RS232 serial port 1 slot for networkinterface connection

Capacitate baterie

12 V / 7 Ah

Incarcare

2700W

Dimensiuni

322 x 189 x 444 mm

Altele

Tower

Altii

2xSHKIN 1x C13

Producator

LEGRAND

Garantie

Recenzii (0)
0 reviews
0
0
0
0
0

Nu există recenzii până acum.

Fii primul care scrii o recenzie pentru „UPS Legrand Keor LP FR On-Line Dubla Conversie 3000VA 2700W,”

Adresa ta de email nu va fi publicată. Câmpurile obligatorii sunt marcate cu *

Întrebări și răspunsuri
Loading...
Informații despre vânzător

Informații despre vânzător

  • Nicio evaluare găsită până acum!
Întreabă vânzătorul

Întreabă vânzătorul

Please Login to make enquiry about this product